SHANGHAI CHANNELMED IMP. & EXP. CO., LTD.

YIXING SUNDLN LATEX PRODUCTION CO., LTD.

WEBEST (CHINA) MEDICAL PRODUCT CO., LTD.

YANGZHOU SUPER UNION MEDICAL MATERIAL CO., LTD.

XIANTAO XINGYUAN NONWOVEN PRODUCTS FACTORY

Uritest 3000 /19 Parameters
Automated Hematology Analyzer

Specifications:
• Parameters: WBC, LY#, MO#, GR#, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT 3-part differentiation of WBC, 19 parameters + 3 histograms
• Sample Mode: Whole blood & Pre-diluted
• Sample Volume: Venous 18ul, Capillary 20ul
• Reagent: 0.7ml lytic reagent and 40ml diluent per test
• Throughput: Up to 60 samples per hour
• Data storage: 2000 samples
• Display: 5.5 inches LCD, resolution 320 x 240
• Dimension: 460 x 300 x 420mm
• N.W.: 17kgs
• Power requirement: AC 100V --- 240V, 50/60Hz
• Input/Output: System keyboard, Built-in thermal recorder,Optional external printer, RS232 interfacing to computer ,Db25 connector interfacing to printer (LQ850 supported)

Characteristics:
• High reliability : concise design
• Low cost : no standby consumption,detergent needed only in tubing maintenance
• High efficiency : easy key-board operation
• High precision : independent stepmeroe & helic rinse
• High automatization : probe cleaning, hemolysis, counting, tubing rinse and printing automatically

Botest3100/19 Parameters Automated Hematology Analyzer

Specifications:
• Parameters: WBC, LY#, MO#, GR#, LY%, MO%, GR%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT 3-part differentiation of WBC: 19 parameters + 3 histograms
• Sample Mode: Whole blood & Pre-diluted
• Sample Volume: Venous 18ul, Capillary 20ul
• Reagent: 0.7ml lytic reagent and 40ml diluent per test
• Throughput: Up to 60 samples per hour
• Data storage: 20000 samples
• Display: 10.4 inches TFT
• Dimension: 500mm x 372mm x 420mm
• N.W.:25kgs
• Power requirement: AC 100V --- 240V, 50/60Hz
• Input/Output: WINDOWS CE 4.2 operation system, Standard keyboard & PC mouse. Built-in thermal recorder ,optional Rs232 & USB interfacing to external laser or inkjet printer

Characteristics:
• Large display& Window operation system, friendly to customer
• Large storage, convenient to inquiry
• Energy saving function
• Fully automated, compact, flexible and high accuracy
• Intelligent cleaning technology
• Alarm marking: 8 group human clinical database

Major parameter and precision
   

Best viewed in 1024 X 768 pixels

©2006 by channelmed.com All rights reserved.

E-mail: info@channelmed.com   channelmed@hotmail.com